  Datasheet File OCR Text:
 AC-DC
15 Watts AEL Series
* * * * * * *
xppower.com
CEC 2008 & EISA 2007 Compliant Approved as LPS China Compulsory Certfication (CCC) Qualified High Efficiency +70 C Operating Temperature Compact Dimensions Optional Input Connector
Specification
Input
Input Voltage Input Frequency Input Current Inrush Current Earth Leakage Current Power Factor Input Protection Standby Power Consumption * * * * * * * * 90-264 VAC 47-63 Hz 0.4 A at 115 VAC 15 A/30 A for 115 VAC/230 VAC, cold start 0.75 mA at 240 VAC Meets EN61000-3-2 Fitted with internal fuse Typically 0.3 W, max 0.5 W
General
Efficiency Isolation * 85% typical * 3000 VAC Input to Output 1500 VAC Input to Ground 500 VDC Output to Ground * 63 kHz typical * 300 kHrs to MIL-STD-217F
Switching Frequency MTBF
Environmental
Operating Temperature * 0 C to +70 C, derate from 100% power at +40 C to 50% power at +70 C Storage Temperature * -40 C to +85 C Cooling * Convection cooled Operating Humidity * 5-95% RH, non-condensing Operating Altitude * 3000 m Shock * 10 g, 10 ms on 3 axes Vibration * 5-100 Hz 2.31 m/s2, 20 mins 3 axes
Output
Output Voltage Minimum Load Hold Up Time Start Up Delay Transient Response Line Regulation Load Regulation Ripple & Noise Short Circuit Protection Temperature Coefficient * * * * * * * * * * See tables No minimum load required 5 ms min at full load 110 VAC 2.0 s at full load 100 VAC 2% deviation, recovery to within 1% of nominal in 4 ms for 50% load change See tables See tables 1% pk-pk max, 20 MHz BW. See note 3. Trip & restart (Hiccup mode), auto recovery 0.04%/C
EMC & Safety
Emissions Harmonic Current Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Magnetic Field Dips & Interruptions * EN55022 FCC Part-15C Level B conducted & radiated * EN61000-3-2 Class A * EN61000-3-3 * EN61000-4-2 Level 3 Perf criteria A * EN61000-4-3 3 V/m Perf criteria A * EN61000-4-4 Level 2 Perf criteria A * EN61000-4-5 Level 3 Perf criteria A * EN61000-4-6 Level 2 Perf criteria A * EN61000-4-8 1 A/m Perf criteria A * EN61000-4-11, 70% UT for 500 ms, 40% UT for 100 ms, <5% UT for 5000 ms Perf criteria A, B, B * EN60950-1:2001, UL/cUL60950-1, Approved as Limited Power Source, CE Mark, China Compulsory Certification (CCC) qualified.
Safety Approvals
AC-DC
Models and Ratings
Max Output Power 8W 12 W Output Voltage (4) 3.3 VDC 5 VDC 8 VDC 9 VDC 12 VDC 15 VDC 15 W 18 VDC 24 VDC 30 VDC 36 VDC 48 VDC Output Current 2.50 A 2.40 A 1.87 A 1.66 A 1.25 A 1.00 A 0.83 A 0.62 A 0.50 A 0.42 A 0.31 A Total Regulation(2) 7% 7% 5% 5% 5% 5% 5% 5% 5% 3% 3%
AEL15
Model Number(1) AEL15US03 AEL15US05 AEL15US08 AEL15US09 AEL15US12 AEL15US15 AEL15US18 AEL15US24 AEL15US30 AEL15US36 AEL15US48
Notes
1. 2. 3. 4. Standard input connector is IEC320-C14 Inlet. For optional IEC320-C6 Inlet, add suffix "C6" to model number e.g. AEL15US12C6. Total regulation includes initial set accuracy, line regulation, load regulation and temperature coefficient. Measured at 25 C Other output voltages available, contact sales for details.
Mechanical Details
3.58 0.04 (91.0 1.0)
AC INPUT IEC-320-C6 INLET
AC INPUT IEC-320-C14 INLET
Notes
1. 2. 3. 4. 5. 6. 7. All dimensions are shown in inches (mm). Tolerance 0.04 (1.0) max. Output connector: is 0.22 (5.5) outer diameter barrel, 0.10 (2.5) inner diameter barrel with centre positive (+) and outer shell negative (-). Length is 0.433 (11.0). Output cable length is 48" (1220mm) approx. Weight is 0.36 lbs (165 g) For European mains lead order part: EU-MAINS-IEC or EU-MAINS-5 for C6 version. For UK mains lead order part: UK-MAINS-IEC or UK-MAINS-5 for C6 version. For US mains lead order part: US-MAINS-IEC or US-MAINS-5 for C6 version.
1.42 0.04 (36.0 1.0)
1.50 0.04 (38.0 1.0)
01-Dec-08
AC-DC
20-60 Watts AEL Series
* * * * * * *
xppower.com
CEC 2008 & EISA 2007 Compliant Approved as LPS China Compulsory Certfication (CCC) Qualified Up to 88% Efficiency +70 C Operating Temperature Compact Dimensions 20 W Optional Class II Insulation
Specification
Input
Input Voltage Input Frequency Input Current * 90-264 VAC * 47-63 Hz * 0.4 A max AEL20 1.0 A max AEL40 1.6 A max AEL60 Inrush Current * 15 A/30 A for 115 VAC/230 VAC, cold start Earth Leakage Current * 0.75 mA at 240 VAC (except C2 version) Power Factor * Meets EN61000-3-2 Input Protection * Fitted with internal fuse, 1 A AEL20, 2 A AEL40/60 Standby Power * Typically 0.3 W, max 0.5 W Consumption
General
Efficiency Isolation * 85% typical AEL20/40, 88% typical AEL60 * 3000 VAC Input to Output 1500 VAC Input to Ground (not C2 version) 500 VDC Output to Ground (not C2 version) * 63 kHz typical * 300 kHrs AEL20, 200 kHrs AEL40, 130 kHrs AEL60 to MIL-STD-217F
Switching Frequency MTBF
Environmental
Operating Temperature * 0 C to +70 C, derate from 100% power at +40 C to 50% power at +70 C Storage Temperature * -40 C to +85 C Cooling * Convection cooled Operating Humidity * 5-95% RH, non-condensing Operating Altitude * 3000 m Shock * 10 g, 10 ms on 3 axes Vibration * 5-100 Hz 2.31 m/s2, 20 mins 3 axes
Output
* See tables * No minimum load required * 12 ms min AEL20, 16 ms AEL40/60, at full load 110 VAC Start Up Delay * 0.5 s AEL20/40, 2.0 s AEL60, at full load 100 VAC Transient Response * 2% deviation, recovery to within 1% of nominal in 500 s for 50% load change Line Regulation * See tables Load Regulation * See tables Ripple & Noise * 1% pk-pk max, 20 MHz BW Overvoltage Protection * 112-132% Overload Protection * 110-150% Short Circuit Protection * Trip & restart (Hiccup mode), auto recovery Temperature * 0.04%/C Coefficient Output Voltage Minimum Load Hold Up Time
EMC & Safety
Emissions Harmonic Current Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Magnetic Field Dips & Interruptions * EN55022 FCC Part-15C Level B conducted & radiated * EN61000-3-2 Class A * EN61000-3-3 * EN61000-4-2 Level 3 Perf criteria A * EN61000-4-3 3 V/m Perf criteria A * EN61000-4-4 Level 2 Perf criteria A * EN61000-4-5 Level 3 Perf criteria A * EN61000-4-6 Level 2 Perf criteria A * EN61000-4-8 1 A/m Perf criteria A * EN61000-4-11, 70% UT for 500 ms, 40% UT for 100 ms, <5% UT for 5000 ms Perf criteria A, B, B * EN60950-1:2001, UL/cUL60950-1, Approved as Limited Power Source, CE Mark, China Compulsory Certification (CCC) qualified.
Safety Approvals
AC-DC
Models and Ratings
Max Output Power 15 W Output Voltage(3) 5 VDC 12 VDC 15 VDC 20 W 24 VDC 30 VDC 48 VDC Output Current 3.00 A 1.67 A 1.33 A 0.83 A 0.67 A 0.42 A Total Regulation(2) 5% 4% 4% 3% 3% 3%
AEL20
Model Number(1) AEL20US05 AEL20US12 AEL20US15 AEL20US24 AEL20US30 AEL20US48
Notes
1. For optional Class II version on AEL20 models only, add suffix `C2' to model number e.g. AEL20US12C2. 2. Total regulation includes initial set accuracy, line regulation, load regulation and temperature coefficient. 3. Other output voltages available, contact sales for details.
Mechanical Details
3.90 (99.0) 0.02 (0.5)
1.65 (42.0)
AC INPUT IEC-320-C6 INLET
AC INPUT IEC-320-C8 INLET (Optional C2 Version)
Notes
1. 2. 3. 4. 5. 6. 7. All dimensions are shown in inches (mm). Tolerance 0.04 (1.0) max. Output connector: is 0.22 (5.5) outer diameter barrel, 0.10 (2.5) inner diameter barrel with centre positive (+) and outer shell negative (-). Length is 0.433 (11.0). Output cable length is 48" (1220mm) approx. Weight is 0.37 lbs (170 g) For European mains lead order part: EU-MAINS-C5 for AEL20, EU-MAINS-8 for AEL20 Class II. For UK mains lead order part: UK-MAINS-5 for AEL20, UK-MAINS-8 for AEL20 Class II. For US mains lead order part: US-MAINS-5 for AEL20, US-MAINS-8 for AEL20 Class II.
1.22 (31.0)
0.04 (1.0)
AC-DC
Models and Ratings
Max Output Power 25 W 35 W Output Voltage(2) 5 VDC 8 VDC 9 VDC 12 VDC 15 VDC 40 W 18 VDC 24 VDC 36 VDC 48 VDC Output Current 5.00 A 4.37 A 3.88 A 3.33 A 2.67 A 2.22 A 1.67 A 1.11 A 0.83 A Total Regulation(1) 7% 5% 5% 5% 5% 5% 3% 3% 3%
AEL40
Model Number AEL40US05 AEL40US08 AEL40US09 AEL40US12 AEL40US15 AEL40US18 AEL40US24 AEL40US36 AEL40US48
Notes
1. Total regulation includes initial set accuracy, line regulation, load regulation and temperature coefficient. 2. Other output voltages available, contact sales for details.
Mechanical Details
4.65 (118.00)
0.040.004 (1.000.10)
0.02 (0.50)
AC INPUT IEC-320-C14 INLET
Notes
1. 2. 3. 4. 5. 6. 7. All dimensions are shown in inches (mm). Tolerance 0.04 (1.0) max. Output connector: is 0.22 (5.5) outer diameter barrel, 0.10 (2.5) inner diameter barrel with centre positive (+) and outer shell negative (-). Length is 0.433 (11.0). Output cable length is 48" (1220mm) approx. Weight is 0.70 lbs (300 g). For European mains lead order part: EU-MAINS-IEC. For UK mains lead order part: UK-MAINS-IEC. For US mains lead order part: US-MAINS-IEC.
2.05 (52.00)
1.36 (34.50)
0.04 (1.0)
AC-DC
Models and Ratings
Max Output Power 57 W Output Voltage(2) 12 VDC 15 VDC 18 VDC 63 W 24 VDC 30 VDC 36 VDC 48 VDC Output Current 4.75 A 4.20 A 3.50 A 2.63 A 2.15 A 1.75 A 1.31 A Total Regulation(1) 5% 5% 5% 5% 5% 3% 3%
AEL60
Model Number AEL60US12 AEL60US15 AEL60US18 AEL60US24 AEL60US30 AEL60US36 AEL60US48
Notes
1. Total regulation includes initial set accuracy, line regulation, load regulation and temperature coefficient. 2. Other output voltages available, contact sales for details.
Mechanical Details
4.65 (118.00)
0.040.004 (1.000.10)
0.02 (0.50)
AC INPUT IEC-320-C14 INLET
Notes
1. 2. 3. 4. 5. 6. 7. All dimensions are shown in inches (mm). Tolerance 0.04 (1.0) max. Output connector: is 0.22 (5.5) outer diameter barrel, 0.10 (2.5) inner diameter barrel with centre positive (+) and outer shell negative (-). Length is 0.433 (11.0). Output cable length is 48" (1220mm) approx. Weight 0.70 lbs (300 g). For European mains lead order part: EU-MAINS-IEC. For UK mains lead order part: UK-MAINS-IEC. For US mains lead order part: US-MAINS-IEC.
2.05 (52.00)
1.36 (34.50)
0.04 (1.0)
01-Dec-08
AC-DC
80 Watts AEL80 Series
* * * * * *
xppower.com
CEC 2008 & EISA 2007 Compliant China Compulsory Certfication (CCC) Qualified Output Voltages from 12 to 48 VDC High Efficiency +70 C Operating Temperature Compact Dimensions
Specification
Input
Input Voltage Input Frequency Input Current Inrush Current Earth Leakage Current Power Factor Input Protection Standby Power Consumption * * * * * * * * 90-264 VAC 47-63 Hz 1.1 A max 15 A/30 A for 115 VAC/230 VAC, cold start 0.75 mA at 240 VAC Meets EN61000-3-2 Fitted with internal fuse Typically 0.3 W, max 0.5 W
General
Efficiency Isolation * 85% minimum * 3000 VAC Input to Output 1500 VAC Input to Ground 500 VDC Output to Ground * 63 kHz typical * 300 kHrs to MIL-STD-217F
Switching Frequency MTBF
Environmental
Operating Temperature * 0 C to +70 C, derate from 100% power at +40 C to 50% power at +70 C Storage Temperature * -40 C to +85 C Cooling * Convection cooled Operating Humidity * 5-95% RH, non-condensing Operating Altitude * 3000 m Shock * 10 g, 10 ms on 3 axes Vibration * 5-100 Hz 2.31 m/s2, 20 mins 3 axes
Output
Output Voltage Minimum Load Hold Up Time Start Up Delay Transient Response Line Regulation Load Regulation Ripple & Noise Overvoltage Protection Overload Protection Short Circuit Protection Temperature Coefficient * * * * * * * * * * * * See tables No minimum load required 16 ms min at full load 110 VAC 2.0 s at full load 100 VAC 2% deviation, recovery to within 1% of nominal in 500 s for 50% load change See tables See tables 1% pk-pk max, 20 MHz BW 112-132% 110-150% Trip & restart (Hiccup mode), auto recovery 0.04%/C
EMC & Safety
Emissions Harmonic Current Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Magnetic Field Dips & Interruptions * EN55022 FCC Part-15C Level B conducted & radiated * EN61000-3-2 Class A * EN61000-3-3 * EN61000-4-2 Level 3 Perf criteria A * EN61000-4-3 3 V/m Perf criteria A * EN61000-4-4 Level 2 Perf criteria A * EN61000-4-5 Level 3 Perf criteria A * EN61000-4-6 Level 2 Perf criteria A * EN61000-4-8 1 A/m Perf criteria A * EN61000-4-11, 70% UT for 500 ms, 40% UT for 100 ms, <5% UT for 5000 ms Perf criteria A, B, B * EN60950-1:2001, UL/cUL60950-1, China Compulsory Certification (CCC) qualified, CE Mark.
Safety Approvals
AC-DC
Models and Ratings
Max Output Power Output Voltage(2) 12 VDC 15 VDC 18 VDC 80 W 24 VDC 30 VDC 36 VDC 48 VDC Output Current 6.66 A 5.38 A 4.44 A 3.33 A 2.66 A 2.22 A 1.66 A Total Regulation(1) 5% 5% 5% 5% 5% 5% 5%
AEL80
Model Number AEL80US12 AEL80US15 AEL80US18 AEL80US24 AEL80US30 AEL80US36 AEL80US48
Notes
1. Total regulation includes initial set accuracy, line regulation, load regulation and temperature coefficient. 2. Other output voltages available, contact sales for details.
Mechanical Details
AC Input IEC 320-C14 Inlet
1.69 (43.0)
2.99 (76.0) 5.75 (146.0) 1.0 DC Output
3 5 2 1 4
DC Output 5 Pin Plug
Pin Connections Pin 1 2 3 4 5 Shell Function RTN RTN +ve RTN +ve GND
Notes
1. 2. 3. 4. 5. 6. 7. All dimensions are shown in inches (mm). Tolerance 0.04 (1.0) max. Output connector: 5 pin 180 DIN Output cable length is 48" (1220mm) approx. Weight is 1.5 lbs (700 g) For European mains lead order part: EU-MAINS-IEC. For UK mains lead order part: UK-MAINS-IEC. For US mains lead order part: US-MAINS-IEC.
01-Dec-08


▲Up To Search▲   

 
Price & Availability of AEL80US12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X